| Noise Level (without Vibration Input) | ACC<0.25 M/s2, VEL<0.5mm/s, Disp<1m |
|---|---|
| Frequency Response Accuracy | 5% + 2 Digits |
| Non-linearity | 5% + 2 Digits |
| Operation Temperature Range | 0 - 50C |
| Pickup | Accelerometer With Extension Stinger And Magnetic Mount |
| Noise Level (without Vibration Input) | ACC<0.25 M/s2, VEL<0.5mm/s, Disp<1m |
|---|---|
| Frequency Response Accuracy | 5% + 2 Digits |
| Non-linearity | 5% + 2 Digits |
| Operation Temperature Range | 0 - 50C |
| Pickup | Accelerometer With Extension Stinger And Magnetic Mount, Optional Tacho-sensor |
| Magnifying Power Of The Microscope | 37.5x, 75x |
|---|---|
| Height Of Test Piece (max) | 260 Mm |
| Effective Test Width | 200 Mm |
| Power Supply Voltage | AC 220V |
| Dimension Of The Outward Configuration | 660 X 300 X 900 Mm |
| Parameter | Displacement Peak-peak (micron) |
|---|---|
| Range | 1~500 Micron 2~500 Micron |
| Operation Temperature Range | 0 - 50C |
| Size | 160mm X 25mm X 17mm (WxDxH) |
| Weight | 120 Gram (including Battery) |
| Measurement Parameter | RMS Of Vibration Velocity (mm/s) |
|---|---|
| Range | 1mm/s~50mm/s At20~1000Hz, 5% |
| Operation Temperature Range | 0 - 50C |
| Size | 160mm X 25mm X 17mm (WxDxH) |
| Weight | 120 Gram (including Battery) |
| Parameter | Displacement Peak-peak (micron), Velocity,Acceleration Peak |
|---|---|
| Range | Velocity RMS: 1~50mm/s, 10-1000 Hz Displacement Peak_Peak: 7~500 Micron, 20-400 Hz Acceleration Peak: 1~50 M/s2 ,10-950 Hz |
| Operation Temperature Range | 0 - 50C |
| Size | 160mm X 25mm X 17mm (WxDxH) |
| Weight | 120 Gram (including Battery) |
| PLC Control | PLC Independently Controls The Grinding Disc And Sample Disc |
|---|---|
| Working Mode | Automatic Mode And Manual Mode |
| Operation | Touch Screen |
| Memory | U Memory Disk Store 300 Process, Can Be Imported And Exported |
| Interface | English Interface |
| Operating Principle | ULTROSONIC |
|---|---|
| Measuring Range | 0.15mm – 1800mm |
| Sound Velocity | 400-19999m/s |
| Display | 3.5 "QVGA (320 × 240) Color TFT-LCD Screen |
| Resolution | 0.1mm、0.01mm、0.001mm(0.01inch、0.001inch、0.0001inch) |
| Size | 204 X 100 X 36 (mm) |
|---|---|
| Data Storage | It Can Store 100,000 Thicknesses (100 Groups, 1000 In Each Group), 500 Groups Of A-scan Waveforms And 500 Groups Of B-scan Waveforms At The Same Time |
| Battery | 4pcs AA Dry Battery |
| Measurement Mode | (1) MB-E: The Measurement Mode Based On The Transit Time From The Initial Echo To The First Bottom Echo; (2) E-E: Penetration Coating Measurement Mode, The Arbitrary Em–En Echo Is Optional; (3) ME-E: Multiple Echo Measurement Mode; (4) THIN: Thin Wall Meas |
| Accuracy | +/-0.001mm |
| Delicate Gain | From 0dB To 48dB In 0.5dB Steps |
|---|---|
| Frequency | 2 Independently-selectable Frequencies |
| Channel | 2 Independent Channel |
| Battery | Low-power, Continuous Working Time Up To More Than 10 Hours |
| Product Name | Eddy Current Detector |