Model: TG-100G
Measurement Principle: Coulometric / Electrolytic
Measurement Application: Coating & Plating Thickness
Substrate: Metal & Non-metal
Measurement Range: 0.03~300μm
Indication Error: ≤ 10%
Resolution: 0.01 μm
Measuring Materials: Cd,Co,Pb,Cr, Ni, Cu, Zn, Sn, Ag, Au, Etc.
Probe: 2.4 Mm / 1.7 Mm
Data Storage: PC Database
Report: A4 Testing Report
Power Supply: AC 220V, AC 110V
Application: Automotive, Motorcycle, Sanitary Ware, NdFeB
Brand: HUATEC
Highlight:

HUATEC TG-100G electrolytic thickness gauge

,

coulometric thickness tester with printer

,

electrolytic thickness gauge for metal testing

Basic Infomation
Place of Origin: China
Brand Name: HUATEC
Certification: ISO CE
Model Number: TG-100G
Payment & Shipping Terms
Packaging Details: export standard carton package
Delivery Time: 3 working days
Payment Terms: L/C,T/T
Supply Ability: 500 per month
Product Description

HUATEC TG-100G Electrolytic Coulometric Coating Thickness Gauge

Electrolytic (coulomb) Thickness Gauge Coulometric ThicknessElectrolytic (coulomb) Thickness Gauge Coulometric Thickness Tester

General introduction

1. TG-100G is more focused on the automobile, motorcycle, and sanitary ware industries, because these industries will use the potential difference function. And neodymium iron boron industry, to solve the test problems of the underlying nickel. Automobiles such as: signs, car door locks, car handles, car interior parts, motorcycles such as mufflers, motorcycle, brackets, sanitary wares such as: mixing water valves, towel racks, neodymium Iron-boron: mainly nickel-copper-nickel electroplating.


2. The surface of Ndfeb products is microporous. In the process of electrodeposition, nickel deposition penetrates into the pores of the matrix, forming an invisible interface. Therefore, there is no potential mutation unique to the conventional interface, and the conventional thickness measuring instrument cannot correctly determine the measurement end point.


3. Using TG-100G electrolytic thickness measuring instrument, using the thickness and potential measurement method can effectively solve the problem of Ndfeb permanent magnet coating measurement.


4. Multi-layer nickel coating is measured by TG-100G electrolytic thickness meter, which can analyze the thickness and potential difference of each nickel layer by curve.


5. Can be changed to two kinds of probe, usually 2.4mm and 1.7mm


6. Data can be stored in the computer at any time


7. Test report can be printed by A4 paper


8. Meet standards ASTM B764,DIN EN ISO 16866, Standard Test Method for Simultaneous Thickness and Electrode Potential Determination of Individual Layers in Multilayer Nickel Deposit (STEP Test)

Measure the thickness of electroplating on extremely thin wire with a diameter of only 0.025mm


Technical specification

 

Plating type

Single metal paiting layer

Composite multiple plating layer

Alloy plating layer

Multi-layer nickel

Cr,Ni,Cu, Zn,Sn,Ag, Au,Cd,Co, Pb etc.

Cr/Ni/Cu etc.

NiP,ZnNi, SZn,SPb etc.

The thickness of each layer of multilayer nickel and the potential difference between nickel layers

Substrate

Metal

Non-metal

Steel,copper,copper alloys, die-cast zinc,aluminum etc

Plastic,neodymium iron boron,ceramics etc

Measuring range

0.03~300μm

The best use range 0.03~50um,Over 50um,the error will gradually become larger

Resolution

0.01um

Repeatability

≤5%

Indication error

≤10%

Potential range

0~3000mv

Potential accuracy

0.01mv

Probe size

Standard:φ2.4,φ1.7(unit:mm)
Optional:φ1.2,φ1.0,φ0.8(unit:mm)

Wire test

Diameter 0.050~4mm
multi-layer coating thickness on the cylindrical surface, without conversion, direct reading

Test stand

Standard:STD07
Optional:STD16,STD19,STD-W wire test stand

Calibration

Factory calibration
calibrate a single coating with calibration foils or uniformly calibrate

Stop measurement

Automatic judgment

Stand-alone use

When not measuring the potential difference

Print

A laser or inkjet printer can be purchased separately to print A4 format test results, Excel format, content can be customized
In stand-alone use, a thermal printer can be used to print the test results

Print Content

Plating type, single measurement value, average value, maximum value, minimum value, standard deviation, coefficient of variation, time
Thickness-potential curve

Display mode

Online use:PC Screen display
Stand-alone use:126*64 dot LCD screen

Data stroage

PC Database

Test Hot Key

Stand-aone use,you can customize the hot key for single plating or multiple plating/substrate combination

Curve Analysis

can be displayed on the same screen and modified at will

Pause test

For thick coatings, you can pause at any time and continue the test after changing the electrolyte

Data check

multiple query methods

Operating system

win7,win10

Software upgrade

New products in December 2019, continuous upgrade

Power Supply

AC 220V, AC 110V can be customized

Host Size

200*255*161(mm)