Specifications
Working Temperature: -10 ~ +40 C
Storage Temperature: -20 ~ 50 C
Relative Humidity: <80% Non Condensation
Work Temperature Rise: <18 C
AC Minimum Power Hoisting Power: >4.5kg (44N)
DC Minimum Power Hoisting Power: >18.1kg (177N)
Sensitivity: A1 Standard Test Piece 15/50 Groove Clearly Displayed.
Battery Working Time: 8 Hours
Highlight:

magnetic flaw detector

,

magnetic strenght meter

Basic Infomation
Place of Origin: CHINA
Brand Name: HUATEC
Certification: ISO CE
Model Number: HCDX-Y7T
Payment & Shipping Terms
Packaging Details: Standard Export Carton
Payment Terms: T/T, Western Union
Supply Ability: 500
Product Description

An overview of Electromagnetic AC/DC yoke

 

Handy Magna Yoke Model HCDX-Y7T, charging type magnetic particle flaw detector has the characteristics of compact structure, reasonable layout, small size, light weight and convenient portability. The flaw detector can be used directly in alternating current, and can also be used for AC magnetization power supply (AC battery pack) and DC magnetized power supply (DC-AC inverter battery pack), which is efficient and portable. It is suitable for hull weld inspection, high altitude steel structure weld detection and pressure vessel internal operation. This instrument is suitable for steel structure parts of power, metallurgy, petrochemical, machinery and other industries, such as boiler, pressure vessel, pressure pipe, ship body weld and welding structure of various types of ferromagnetic material surface and magnetic particle flaw detection of near surface defect.

 

This instrument conforms to the standard requirements of JB/T7411-2012, ASME BPVC,ASTM E709,ASTM E1444,ASTM E3024."electromagnetic yoke flaw detector technical condition".

 

Product features

Complete Sealed, durable construction

Chemical and abrasion resistant

DC-AC inverter battery design,AC and DC operation options for surface and sub-surface inspection

Exceeds ASTM lifting specifications

 

The three modes of power supply can be freely chosen:

There are places directly connected to AC power supply, which can be directly connected with AC power supply.

It is possible to use AC magnetized power supply (DC-AC inverter battery pack) to supply AC power without any direct insertion to AC power supply.

The DC magnetizing power supply (DC battery pack) can be used to realize the DC magnetization function.

AC magnetizing power supply (DC-AC inverter battery pack) has the functions of voltage regulation, overcharge, over current and over discharge.

When the lifting force is not enough, the power is automatically cut off to ensure the sensitivity of flaw detection.

The power display function can display the current battery power, and has the function of sound and light alarm.

Built in microcomputer chip to stabilize output voltage and ensure detection sensitivity.

Adjustable magnetization

Special working waist bag can carry battery pack, magnetic suspension, contrast agent, yoke probe, etc.

 

 

Customer model guide

Electromagnetic Yoke HCDX-Y1 HCDX-Y7 HCDX-Y7L HCDX-Y7T
Electrode spacing 0~210mm 0~210mm 0~210mm 0~210mm
Maximum current 2.8A 2.8A 2.8A 2.8A
weight 2.2kg 2.4kg 2.4kg 2.6kg
major function Direct alternating current magnetization

Direct alternating current magnetization

DC magnetization of rechargeable battery pack MT-500

Direct alternating current magnetization

AC magnetization of rechargeable battery pack MT-600

Direct alternating current magnetizatio,

AC magnetization of rechargeable battery pack MT-610

Ac / Dc Battery Magnetic Particle Yoke 0

 

Technical parameter

Working temperature: -10 ~ +40 C

Storage temperature: -20 ~ 50 C

Relative humidity: <80% non condensation

Work temperature rise: <18 C

Temporary load rate: >50%

Sensitivity: A1 standard test piece 15/50 groove clearly displayed.

AC minimum power hoisting power: >4.5kg (44N)

DC minimum power hoisting power: >18.1kg (177N)

 

Standard configuration:

HCDX-Y7T

Magnetic powder flaw detector host 1

Power line 1

Rechargeable type DC-AC inverter battery pack MT610 (AC magnetization power supply) 1

AC power backpack 1

Power adapter 1

AC output connection line 1

Instrument box 1

 

Defect examples:                                                           Defect location:

Inclusions Seams                                                              Surface and subsurface Ideal for: Fatigue cracks

Shrink cracks Tears Laps                                                  Field testing pot inspections

Welding slag Grinding cracks                                            In-service inspections

Quenching cracks                                                              Demanding environments

                                                                                          Weld inspection