Live A-Scan / Time-based B-Scan Paint Thickness Gauge TG5000 Series Ultrasonic
Features:
Color 320x240 Pixels Display
LiveSimultaneous Color A-Scan and Thickness Display
Control of Gain, Blanking, Gate, Range, Delay, RF and Rectify Modes
Time-based B-Scan Display
Echo-Echo Mode(Thru Paint & Coatings)
Stores 100,000 Readings and 1000 waveform
Specifications
Feature |
TG-5000 |
TG-5000D |
TG-5000DL |
Data Logger Option |
Color Display |
|
|
|
|
Live A-Scan |
|
|
|
|
Time-based B-Scan |
|
|
|
|
Control of Gain, Blanking, Gate, Range, Delay, RF and Rectify Modes |
|
|
|
|
Echo-Echo Mode (Thru Paint & Coatings) |
X |
|
|
|
Data Logger |
X |
X |
|
|
Data View Software |
X |
X |
|
|
Instrument Specifications |
|
Display Type |
2.4" color OLED, 320X240 pixels, contrast 10,000:1 |
Operating Principle |
Pulse echo with dual element transducers |
Measuring Range |
0.50mm to 508mm(0.02" to 20.00"), depending on material, probe and surface condition |
Through Coating Function | Coating thickness:0-8mm;Measuring range:3-50mm |
MeasuringResolution |
Selectable 0.01mm, 0.1mm(selectable 0.001", 0.01") |
Units |
Inch or Millimeter |
Rectify Modes |
RF+, RF-, HALF+, HALF-, FULL |
Display Mode |
Normal, Minimum / Maximum capture, DIFF/RR%, A-Scan, B-Scan |
V-Path Correction |
Automatic |
Update Rate |
Selectable 4Hz, 8Hz, 16Hz |
MaterialVelocity Range |
500 to 9999m/s (0.0197 to 0.3937in/us) |
Languages |
English |
Alarm Settings |
Minimum and Maximum alarms. Range of 0.25 mm to 508 mm (0.010" to 20.00"). Dynamic waveform color change on alarm |
Power Requirements |
2 AA size batteries |
Operating Time |
Approximately 40 hours |
Instrument Shut-off |
Selectable ALWAYS ON or AUTO OFFafter 5, 10, 20 minutes of inactivity |
Operating Temperature |
-10°C to +50°C (+10°F to +120°F) |
Size |
153mm X 76mm X 37mm(H X W X D) |
Weight |
280g including batteries |
Data Logger Option Features |
|
Capacity |
100,000 readings,1000 waveforms,400 files |
File Structure |
Grid file |
Rows X Columns |
21 X 12 |
CommunicationPort |
USB 2.0 (Full Speed ) port |
Software |
Data View PC software |
TG-5000 Series Probe/Transducer Specifications |
|||||||
Model |
PT08 |
TC510 |
PT12 |
ZT12 |
PT06 |
PT04 |
GT12 |
Type |
TG-5000 |
TG-5000D/DL Standard |
Standard |
Cast iron |
Small tube |
Fingertip |
High-Temperature |
Frequency |
5MHz |
5MHz |
5MHz |
2MHz |
7.5MHz |
10MHz |
5MHz |
Contact Diameter |
11mm |
13.5mm |
13.5mm |
17mm |
8mm |
6mm |
15mm |
MeasurementRange |
0.8 to |
1.2 to |
1.0 to 200.0mm |
4.0 to |
0.8 to |
0.7 to 12.0mm |
4.0 to |
TemperatureRange |
-10 to 70℃ |
-10 to |
-10 to 70℃ |
-10 to 70℃ |
-10 to |
-10 to 70℃ |
-20 to 300℃ |
Standard Configurations |
|
Thickness Gauge |
1 |
Probe |
1 |
Alkaline Battery |
2 |
Couplant |
1 |
Carrying Case |
1 |
Operation Manual |
1 |
USB Cable |
1(Only TG-5000DL) |
Software CD |
1(Only TG-5000DL) |
Optional Configurations |
|
High-temperature Probe |
Cast Iron Probe |
Small Probe |
Mini Probe |
Probe Cable |
Stepped Calibration Block |
Rubber Sheath |
Storage Option(Only TG-5000DL) |