320KV Ceramic tube penetrant 40mm Directional Radiographic inspection machine
Main technical parameters
ITEM |
XXG3205 | ||
Max Penetration thickness Steel (A3) | 55mm | ||
Focal Distance | 600mm | ||
Exposure Time | 5min | ||
Film Type | Agfa D7 | ||
Double lead foil Intensifying screen |
0.03 | ||
Darkroom Disposal | 20±2℃ | ||
Development | 5minutes | ||
Blackness | 1.5 | ||
Input | Voltage (V) | 220V±10% 50―60Hz | |
Capacity (KVA) | 3.2 | ||
Output | Tube voltage (KVP) | 170-320Kv | |
Tube current (mA) | 5 | ||
Stability | ±1% | ||
X-RAY Tube |
Focus mm2 | 2.5×2.5 | |
Radiation Angle | 40±5° | ||
Sensitivity | k≤1.8% | ||
Operation Mode | Intermittent operation, Radiating time to cooling time is 1:1 | ||
X-Ray Controller |
Dimension | 350×290×160 | |
Weight | 11kg | ||
Circuit Structure | Micro-computer control ,Modular structure,Voice prompt | ||
X-RAY Generator |
Cooling | Force air cooling | |
Insulation | SF6 Gas Insulation | ||
Working Pressure | 0.35Mpa-0.45Mpa | ||
Dimension | 335×335×700 | ||
Weight (kg) | 43kg | ||
Working Temperature | -10℃―+40℃ |
Standard Delivery
Directional glass X-ray tube | 1 Pcs | |
Generator | 1 Set | |
High voltage joins cable | 1 Pcs | 25 Meters |
Controller | 1 Set | |
Power cable | 1 Pcs | 10 Meters |
Grounding cable | 1 Pcs | 5 Meters |
Accessories | 1 Set | |
(Including: alarm lamp,1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc) |
System Installation
1.Check and count all goods to be received per the packing list. And then check the quality of the parts for damage,lost and mistake.
2.Keep the controller in a flat,dry and dustless place, switch off the power and connect the power cable.
(Note:
The power supply of the unit is single phase 220V±10% 50-60HZ)
3.If necessary,one end of earth wire can be connected to the earth terminal of the controller and the other end to the special grounding wire.
4.Connect controller to x-ray generator by special 9 cores cable,and form better contact.
5.Check the gas pressure gauge on x-ray generator and make sure it range from 0.35Mpa to 0.45Mpa.If not,the unit is not allowed to turn on so as to avoid any damage to the x-ray generator.
Working Principle
This machine is composed of intelligent controller-ray generator, power cable and connecting cable.
1.The controller will consist of the following sections:
Front Panel: LED display, status and failure indicator, touch keyboards (see the introduction of control panel)
Side Panel: power cable socket and connecting cable socket, power switch,key switch, fuse socket, warning lamp and wire connecting terminal of door-machine interlock.
Internal Circuit: power circuit, rectifying circuit, filter circuit, inverter circuit, control circuit and other circuited.
2.The x-ray generator will consist of the following sections:
X-ray tube, High voltage transformer, Temperature relay, Gas pressure gauge and Cooling fan etc.
3.The schematic diagram of the complete machine:
Optional accessories:
Testing platform, IQI/wire penetrameter, lead letter/digits, lead tape, Cassette, lead screen, personal dosimeter, film viewer, densitometer, film developer, dark room light, RT calibration block etc.