Digital Radiography (DR) System Portable X-ray Machine for Welding Digital Flat Panel
HDR-2530 Digital Radiography (DR) system
Features:
Meet the latest NB/T 47013.11-2015 standard
Digital transformation of X-ray real-time imaging detection system
On-site portable digital imaging inspection
16bit high dynamic range
120μm pixels, high resolution 4.0lp/mm
CsI cesium iodide efficient X-ray image conversion
25cmX30cm imaging field of view
1-Industrial X-ray digital flat panel detector
Basic parameters:
Model | HDR-2530 |
Pixel size | 120 um |
A/D conversion | 16bit |
Scintillator | CsI:TI or GOS |
Dynamic Range | >12000:1 |
Limit spatial resolution | 4.0lp/mm |
Imaging area | 250mm x 300mm |
Pixel matrix | 2560x2048 |
Read rate | 2s |
Energy range | 20-320kV |
Dimensions | 333mm x 282mm x15mm |
Weight | 2kg |
Data interface | Gigabit |
2——Digital image processing and enhancement software
Image enhancement and storage system integration Currently the most practical processing and filtering functions are specially designed for X-ray real-time imaging systems, which can increase the sensitivity of processed images by 0.6%-0.8% on average. With the help of high-speed Ethernet port, it can help you obtain static images and dynamic images at the same time, and save them in 8/16bit image format, and can be directly burned to DVD discs for permanent storage, which is convenient for archiving and review of test data, while saving test Cost and archive space.
Tablet connection and control
Gigabit network flat panel connection, and prompts the connection status and failure
Offset/gain/bad pixel correction
Offset/gain/bad pixel correction, whether to overlap or not can be selected
Display ratio prompt
Current frame rate reminder
Software processing progress display
Pixel gray value display
Real-time image display and processing
Real-time image ROI fast grayscale mapping, which is convenient for fast observation of effective images of the region of interest
Real-time display integral noise reduction: 2/4/8 frame optional
Real-time display algorithm processing: negative film/color/binarization
Real-time display of image sharpening and enhancement
Image integration collection: 8/16/32/64/128/256 frame overlay
Continuous video recording: optional compression format
Picture/video naming and name automatic sequence compilation
0-65536, 16bit gray scale adjustment
Gamma/contrast/brightness/threshold adjustment
Picture information mark, multiple contents are optional
Static image processing
ROI fast grayscale mapping, which is convenient for fast observation of effective images of the region of interest
bmp / png / jpg / tiff(8bit/16bit) / RAW / his / dcm file reading
Grayscale/negative film/false color/binarization/sharpening/enhancement algorithm processing
Magnifying glass, 1-5 times magnification observation
Picture flip
Gamma/contrast/brightness/threshold adjustment
Size calibration and measurement, and the required information can be marked on the picture
Automatic verification of Duplex wire image quality indicator (optional)
Meet the NB/T 47013.11-2015 "Non-destructive testing of pressure equipment X-ray digital imaging testing" standard requirements, automatic verification of the dual-filament image quality indicator, and can determine SNR.
Portable high frequency X-ray flaw detector
Main performance:
Continuous exposure under the conditions of 35℃ 300kv/3mA, 250kv/3mA;
Wide input voltage range to meet the power supply of various generators;
Lightweight, strong penetration, stable performance;
More suitable for use in harsh and humid environments;
The operation interface is intuitive and easy to operate;
Main technical parameters
project name | XXG-300GF | XXG-250GF | |
X-ray generator | Weight | 27kg | 25kg |
Dimensions | Φ295×752 (Φ×L) | Φ295×704 (Φ×L) | |
Controller | Weight | 11kg | 11kg |
Dimensions | 410×228×300 (L×B×H) | 410×228×300 (L×B×H) | |
Focus size | 3.0×3.0 | 3.0×3.0 | |
Radiation angle | 40°×40° | 40°×40° | |
Maximum penetration(Fe) | 70mm (A3) | 60mm (A3) | |
kV Adjustment range | 120~300 kV | 70~250 kV | |
mA Adjustment range | 0.5~3 mA(Stepping 0.1mA) | 0.5~3 mA(Stepping 0.1mA) | |
Maximum power | 900W | 900W | |
Leakage radiation value | maximum 5.0msv/h | maximum 5.0msv/h | |
Operating temperature | -20˚C~+50˚C | -20˚C~+50˚C | |
Storage temperature | -25˚C~+70˚C | -25˚C~+70˚C | |
Voltage | 85~264 VAC | 85~264 VAC | |
Power frequency | 45~65 Hz | 45~65 Hz |