Output: 30-160KV
Input: 1.5KW
Focus Spot: 1.0x1.0
Max Penetration: 18mm
Material: Steel
Radiation Angle: 40±5°
Usage: Industrial X-Ray Testing,weld Testing,Industrial X Ray Testing Machine
Power Supply: AC220V±10%,50HZ
Application: Industrial X-Ray Testing,welding Seam Detecting
Warranty: 12 Months
Exposure Time: 5 Minutes
Controller Size: 350*290*170mm
Generator Size: 225×225×560MM
Generator Weight: 17kg
High Light:

x ray inspection equipment

,

industrial x ray machine

Basic Infomation
Place of Origin: Beijing
Brand Name: HUATEC
Certification: ISO, CE, GOST
Model Number: XXG-1605
Output voltage: 30-160kv
Payment & Shipping Terms
Packaging Details: Standard export plywood package
Delivery Time: 1-4days
Payment Terms: T/T, Paypal, Western Union
Supply Ability: 500pcs per month
Product Description

 
160KV Ceramic tube penetrant 18mm Directional Radiation Portable X-Ray Flaw Detector
 
 
The HUATEC Flaw detector products have been widely used for nondestructive testing in spaceflight industry, welding engineering industry, shipbuilding industry, boiler pipe industry, petrochemical engineering industry, aircraft manufacturing, maintenance industry, automotive industry, defense industries, etc.
Features:
◆ Adopting micro-computer control and modular structure, with strong anti-interference ability and high automaticity and reliable performance.
◆ Parameter setting, working process and trouble indication will be indicated on the LED screen.
◆ Independent aging key is designed for aging the machine conveniently.
◆ Radiating time to cooling time is 1:1.
◆ The controller can recognize the type of x-ray generator automatically.
◆ The water and dust proof color panel and digital sound keyboard are introduced that exposure parameters are promptly and accurately selected.
◆ Ensure safety using the instrument, it is installed with overvoltage, under voltage,
over current, under current and over temperature protection device.
◆ A unique safety lock is designed that protect the operator from the damage of radiation.
◆ Adopting the wider range of KV value, and solve the difficulty problem of short radiographic range.

◆ Exposure delay function ------the delay time can be set less than 10 minutes to keep the operator safe from working place.
◆ Match with various generator and function reliably.
◆ Number of exposure can be accumulated.
(After the unit has been ready, but before press the "ON" key, you can press the "A" key (delay key) three times to check the number of exposure, and press any key to return back.)
◆ With the outlet of ray warning lamp and wire connecting terminal of door-machine interlock.

(Door-machine interlock—when the lead door opens, the instrument cut off the high voltage automatically to protect the operator)
 
 
Main technical parameters XXG1605 Ceramic tube orientation/directional

TYPE

XXG1605
Max Penetration thickness Steel (A3)18mm
Focal Distance600mm
Exposure Time5min
Film TypeAgfa D7

Double lead foil Intensifying screen

0.03
Darkroom Disposal20±2℃
Development5minutes
Blackness1.5
InputVoltage (V)220V±10% 50―60Hz
Capacity (KVA)1.5
OutputTube voltage (KVP)30-160Kv
Tube current (mA)5
Stability±1%

X-RAY
Tube

Focus mm21.0×1.0
Radiation Angle40±5°
Sensitivityk≤1.8%
Operation ModeIntermittent operation, Radiating time to cooling time is 1:1

X-Ray
Controller

Dimension350×290×160
Weight11kg
Circuit StructureMicro-computer control ,Modular structure,Voice prompt

X-RAY
Generator

CoolingForce air cooling
InsulationSF6 Gas Insulation
Working Pressure0.35Mpa-0.45Mpa
Dimension225×225×560
Weight (kg)17kg
Working Temperature-10℃―+40℃

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Working Principle
This machine is composed of intelligent controller-ray generator, power cable and connecting cable.
1.The controller will consist of the following sections:
Front Panel: LED display, status and failure indicator, touch keyboards (see the introduction of control panel)
Side Panel: power cable socket and connecting cable socket, power switch,key switch, fuse socket, warning lamp and wire connecting terminal of door-machine interlock.
 
 
Directional Radiation X-Ray Flaw Detector Steel Material 160KV Ceramic Tube Penetration 18mm 0
Internal Circuit: power circuit, rectifying circuit, filter circuit, inverter circuit, control circuit and other circuited.
2.The x-ray generator will consist of the following sections:
X-ray tube, High voltage transformer, Temperature relay, Gas pressure gauge and Cooling fan etc.
3.The schematic diagram of the complete machine:
 
 Directional Radiation X-Ray Flaw Detector Steel Material 160KV Ceramic Tube Penetration 18mm 1   
 
 
Standard Delivery

Directional glass X-ray tube1 Pcs 
Generator1 Set 
High voltage joins cable1 Pcs25 Meters
Controller1 Set 
Power cable1 Pcs10 Meters
Grounding cable1 Pcs5 Meters
Accessories1 Set 
(Including: alarm lamp,1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc)

 
Optional accessories:
Testing platform, IQI/wire penetrameter, lead letter/digits, lead tape, Cassette, lead screen, personal dosimeter, film viewer, densitometer, film developer, dark room light, RT calibration block etc.
 
Directional Radiation X-Ray Flaw Detector Steel Material 160KV Ceramic Tube Penetration 18mm 2
 
Directional Radiation X-Ray Flaw Detector Steel Material 160KV Ceramic Tube Penetration 18mm 3
 
 
 

Recommended Products
Get in touch with us
Contact Person : JingAn Chen
Tel : 8610 82921131,86 13261934319
Fax : 86-10-82916893
Characters Remaining(20/3000)