| Detection Channel | 1-4 (depending On The Model Configuration) | 
|---|---|
| Frequency Range | 10 Hz-10 MHz, Continuously Adjustable, Up To 2 Simultaneous Detection, Can Be Limited Mixing; ◆ Automatic / Manual Amplitude And Phase Adjustment | 
| Inspection And Marking Accuracy | ≤ ± 50mm | 
| Gain Range | 0.0 ~ 99.0 DB Continuously Adjustable, Step: 0.1 | 
| Missed Rate | ≤ 0%, Misjudgment Rate (mistakenly Qualified Products To Determine Nonconforming Products) ≤ 1% | 
| Detection Channel | 1-4 (depending On The Model Configuration) | 
|---|---|
| Frequency Range | 10 Hz-10 MHz, Continuously Adjustable, Up To 2 Simultaneous Detection, Can Be Limited Mixing; ◆ Automatic / Manual Amplitude And Phase Adjustment | 
| Inspection And Marking Accuracy | ≤ ± 50mm | 
| Gain Range | 0.0 ~ 99.0 DB Continuously Adjustable, Step: 0.1 | 
| Missed Rate | ≤ 0%, Misjudgment Rate (mistakenly Qualified Products To Determine Nonconforming Products) ≤ 1% | 
| Detection Channel | 1-4 (scalable As Needed) | 
|---|---|
| Frequency Range | 5 Hz ~ 12 MHz, Continuously Adjustable, 2-4 Independent Selectable Frequency, Multiple Mixing Unit | 
| Adjustable Detection Range | The Maximum Measurement: 10 ~ 10000, Step 1 | 
| Gain Range | 0.0dB ~ 99.0dB Continuously Adjustable, Step: 0.1dB | 
| Missed Rate | ≤ 0%, False Positive Rate (mistakenly Judged As Qualified Nonconforming Product) ≤ 1% | 
| Accuracy | 5% | 
|---|---|
| Acceleration Amplitude(RMS) | 9.81m/s2(1g)±3% | 
| Output Waveform | Sine Waveform | 
| Waveform Distortion | 5% | 
| Maximum Load | 120Gram | 
| Standard Conformed To | GB/T4340,ASTM E92 | 
|---|---|
| Min Measuring Unit | 0.01µm | 
| Data Output | 8’LCD Screen Display,60 Kinds Of Test Results Storage, Inside Printer, RS-232 | 
| Hardness Measuring Range | 8~2900HV | 
| Method Of Testing Force Applied | Automatic (loading, Dwelling , Unloading) | 
| Hardness Measuring Range | 8~2900HV | 
|---|---|
| Method Of Testing Force Applied | Automatic (loading,Dwelling , Unloading) | 
| Turret Type | Automatic | 
| Test Microscope Magnification | 400X(Measuring),100X(observation)(Optional 50X、200X 、500X,Maximum 1000X) | 
| X-Y Test Sets | Dimension:100*100mm Maximum Movement:25*25mm | 
| Min Measuring Unit | 0.5µm | 
|---|---|
| Data Output | LCD Screen Display | 
| Eyepiece Type | Analog Eyepiece | 
| Max Height Of Specimen | 80mm | 
| Distance Of Indenter To Outer Wall | 95mm | 
| Maximum Test Force | 250kgf | 
|---|---|
| Test Load Resolution | 0.1kgf And Programmable | 
| Minimum Detection Resolution | 0.2um | 
| Objective Magnification | 70X, 140X | 
| Test Force Time | 1-99 Seconds | 
| Material | ABS | 
|---|---|
| Color | White | 
| Parameters | Ra ,Rz, Rq, Rt, Rp ,Rv, R3z, R3y, Rz(JIS), Rs, Rsk, Rsm, Rku, Rmr, Ry(JIS), Rmax,RPc, Rk, Rpk, Rvk, Mr1, Mr2 | 
| Standards | ISO, DIN, ANSI, JIS | 
| Display | 3.5 Inches Color Graphic TFT Touch Screen | 
| Material | ABS | 
|---|---|
| Color | White | 
| Standards | ISO, DIN, ANSI, JIS | 
| Battery | Built-in Lithium Ion Rechargeable Battery And A Charging Control Circuit, High Capacity | 
| Memory | 100 Groups Of Original Data And Waveform |