Pulse Repetition Frequency | 30-3000Hz |
---|---|
Detection Range | 0-25000 Mm, At Steel Velocity |
Sound Velocity | 100~20000m/s |
Working Methods | Pulse Echo, Dual, And Thru-transmission |
Sensitivity | 120 DB Max In Selectable Resolution 0.1, 1.0, 2.0, 6.0 DB |
Color | Gray |
---|---|
Principle | Ultrasonic |
Standard | JBT 9377-2010、ASTM A1038-2005 |
Calibration | Slef Calibration |
Memory | To Save 1000-groups Of Measuring Data And 20-groups Of Calibration Data |
Color | Gray |
---|---|
Principle | UCI Method (Ultrasonic Contact Impedance) |
Standard | JBT 9377-2010、ASTM A1038-2005 |
Calibration | Slef Calibration |
Memory | 50 Sets Of Data Storage -- The Data Includes Time Information |
Display | 11-inch 800X600 TFT Color Display |
---|---|
Memory | In-Built: 16G RAM+4GB FLASH ;SD Card (max To 32G); External: USB Drive |
File & Entry Management System | Flexible Bridging Between Setting (Focal Law & Model), Calibration And Inspection |
Modular Configuration | L-Scan, S-Scan, L-C-Scan, S-C-Scan, Butt-Weld, CrankShaft , Pipeline, TOFD, UT(Conventional), |
DDF | Dynamic Depth Focusing (DDF) |
Probe | Electromagnetic Ultrasonic Thickness Probe |
---|---|
Principle | Electromagnetic Ultrasonic EMAT |
Thickness Measurement Accuracy | 0.04mm, Range 2~120 Mm (Steel) |
Work Clearance / Lift Off: | ≤4mm |
IP Protection | IP65 |
Material | ABS |
---|---|
Measuring Thickness Range | 0.01 Mm ~ 38 M,depending On The Material Being Measured, Probe, Surface Conditions, Temperature And Selected Configuration |
High Resolution | Regular Display Resolution Is 0.001mm, Optional Ultra-high Resolution Can Reach 0.0001mm |
Measurement Units | Millimeters, Inches, Microns And Mils |
High Temperature Measurement | Up To 500°C |
Color | Black |
---|---|
Material | ABS |
Product Name | Ultrasonic Flaw Detector |
Gain | 110dB |
Working Frequency | (0.5-15) MHz |
Pulse Repetition Frequency | 10-2000Hz,precise Adjust, High Speed Scan, No Miss Out |
---|---|
Detection Range | 0-10000 Mm, At Steel Velocity |
Sound Velocity | 100~20000m/s |
Working Methods | Pulse Echo, Dual, And Thru-transmission |
Sensitivity | 120 DB Max In Selectable Resolution 0.1, 1.0, 2.0, 6.0 DB |
Weight | 310g |
---|---|
Data Storage | It Can Store 100,000 Thicknesses (100 Groups, 1000 In Each Group), 500 Groups Of A-scan Waveforms And 500 Groups Of B-scan Waveforms At The Same Time |
Accuracy | +/-0.001mm |
Measurement Range | 0.15mm – 1800mm |
Display | 3.5 "QVGA (320 × 240) Color TFT-LCD Screen |
Display Type | 2.4QVGA(320×240)true Color OLED Screen,contrast 10000:1 |
---|---|
Operating Principle | Adopts Single Delay Probe Ultrasonic Measuring Principle |
Measuring Range | 0.2mm To 25.4mm(0.007874" To 1.00") |
Measuring Resolution | Selectable 0.001mm, 0.01mm Or 0.1mm (selectable 0.0001, 0.001", 0.01") |
Power Requirements | 2 AA Size Batteries |