| Color | Black |
|---|---|
| Principle | Ultrasonic And Dynamic |
| Standard | JBT 9377-2010、ASTM A1038-2005 |
| Calibration | Slef Calibration |
| Memory | 1000 Datas |
| Color | Black |
|---|---|
| Principle | Ultrasonic |
| Standard | JBT 9377-2010、ASTM A1038-2005 |
| Calibration | Slef Calibration |
| Memory | 1000 Datas |
| Material | ABS |
|---|---|
| Testing Range | 1.0~640 Mm |
| Lifting Clearance | Mm(Aluminum), 4mm(Carbon Steel), 3mm(Stainless Steel) |
| Operating Frequency | 2.5MHz~6MHz |
| High Temperature Sound Speed Compensation | Automatic Compensation |
| Principle | Electromagnetic Induction |
|---|---|
| Display Mode | Two Display Modes (SAVE And FREE): Single Testing Value Or Continuous Testing Value |
| Display Units | Two Units Display: Fe% (ferrite Content) And FN (WRC Number, Amount Of Ferrite) |
| Statistics Function | Mean Value, Max Value, Min Value, Standard Deviation Value. |
| Power Off | Auto Power Off Function |
| Frequency | 0.2 – 20 MHz |
|---|---|
| Detection Range | 0 - 10000 Mm |
| Sound Velocity | 100 – 20000 M/s |
| Working Methods | Pulse Echo, Dual, And Thru-transmission |
| Gain Adjustment | (0-110) DB, Step:0.2, 0.5, 1.0, 2.0, 6.0, 12.0, User Definable(0-24), And Locked |
| Standard Mode | 0.8 Mm-- 300.0 Mm |
|---|---|
| Through Coating Mode | 2.5 Mm – 18.0 Mm |
| Resolution | 0.01mm |
| Memory | 500 Datas In 5 Groups, Memory Does Not Lose After Powering Off |
| Sound Velocity | 1000-9999m/s |
| Pulse Repetition Frequency | 30-3000Hz |
|---|---|
| Detection Range | 0-25000 Mm, At Steel Velocity |
| Sound Velocity | 100~20000m/s |
| Working Methods | Pulse Echo, Dual, And Thru-transmission |
| Sensitivity | 120 DB Max In Selectable Resolution 0.1, 1.0, 2.0, 6.0 DB |
| Pulse Repetition Frequency | 10-2000Hz,precise Adjust, High Speed Scan, No Miss Out |
|---|---|
| Detection Range | 0-10000 Mm, At Steel Velocity |
| Sound Velocity | 100~20000m/s |
| Working Methods | Pulse Echo, Dual, And Thru-transmission |
| Sensitivity | 120 DB Max In Selectable Resolution 0.1, 1.0, 2.0, 6.0 DB |
| Standard Mode | 0.8 Mm-- 300.0 Mm |
|---|---|
| Through Coating Mode | 2.5 Mm – 18.0 Mm |
| Resolution | 0.01mm |
| Memory | 500 Datas In 5 Groups, Memory Does Not Lose After Powering Off |
| Sound Velocity | 1000-9999m/s |
| Color | Gray |
|---|---|
| Principle | Ultrasonic |
| Standard | JBT 9377-2010、ASTM A1038-2005 |
| Calibration | Slef Calibration |
| Memory | To Save 1000-groups Of Measuring Data And 20-groups Of Calibration Data |