Specifications
Measurement Technology: Eddy Current
Operating Frequency: 60KHz,240KHz
Display Screen: 240X320 Pixels TFT-LCD
L*B*H: 180*80*30 Mm
Weight: 260g
Power Supply: Lithium Polymer Battery
High Light:

eddy current testing machine

,

magnetic flaw detector

Basic Infomation
Place of Origin: Beijing
Brand Name: HUATEC
Certification: ISO, CE, GOST
Model Number: HEC-102
Payment & Shipping Terms
Packaging Details: Standard export package
Delivery Time: 1-4days
Payment Terms: T/T, Paypal, Western Union
Supply Ability: 500pcs per month
Product Description

Measurement The Purity Of Non-Ferrous Metals Portable Eddy Current Testing Equipment

 

HEC-102 portable eddy current electrical conductivity meter, which are designed for quick testing of material property, such as material separate,quality control,material state check and so on. The products use the electromagnetic induction principle, can test non-ferromagnetic materials Ti – Ag.

 

Working principle

Eddy current exam is an NDT method established on the basis of electromagnetic induction principle; it is suitable for the conductive materials. Put the conductor in the alternating magnetic field, if inductive current exists, namely eddy current. On account of the change of each conductor’s own factors (for example: conductivity, magnetic conductivity, shape, size and flaw, etc), will cause the change of the current, so we can use this phenomenon to judge the conductor’s character or state and whether flaw exists.

Eddy current test is to put the conductor close to the alternating current coil, the coil establishes alternating magnetic field, this alternating magnetic field transits the conductor, and has the electromagnetic induction with it, establishes eddy current in the conductor. The current in the conductor also can produce its own magnetic field and can change the alternating magnetic field to be strong or weak, then causes the change of the voltage and R resistance. Therefore if the conductor’s surface or the near surface has flaw or the metal material changes, the intensity and the distribution of the eddy current will also change, so as the change of the voltage and R resistance, according to this change, the eddy current may indirectly know about the flaw in the conductor and whether the performance of the metal material changed.

 

Main features

★HEC-102 use 12mm 60 KHz probe as standard, 8mm 60 KHz probe optional for small part testing

★HEC-102 use 60 KHz (aviation industry standard) to inspirit, the testing data can be read in two kinds of unit (%IACS and MS/m)

★The products can test electrical conductivity and resistivity at the same time, resistivity can be automatically calculated and display according to the conductivity measurement value.

★HEC-102 include the intelligent temperature and lift-off compensations, can guarantee the testing accuracy of each measurement

★The big typeface and the back light illumination designs are advantageous for users to take the testing data even in low light condition

★The products use the high property battery to make sure it keeps more running time, and easy to carry and to grasp hold

★English language operation menu

★It can store 1000 measurement data, moreover, users can use USB connect the meter to a PC to create testing report (HEC-102 only)

★The measuring unit can be set by itself

★Measuring range can be customized according to user needs

 

Application:

★ Absolute measurement of electrical conductivity of nearly all non-ferrous metals;(Ti – Ag)

★ In the aerospace and automotive industry,monitor the process of heat treatment, the strength and hardness of aluminum alloy

★Test the conductivity when the aluminum have not been oxidized

★ Measurement the purity of non-ferrous metals

★Test the resistivity of conductive materials

★Analyze thermal properties of materials

 

HEC-102 Technical parameters

Hand-held eddy current conductivity tester for NF-metals with automatic normalization of the conductivity values to 20°C through temperature sensor

Measurement technology Eddy current
Operating frequency 60KHz,120KHz
Display screen 240X320 pixels TFT-LCD
Size L*B*H 180*90*40 mm
Instrument case Anti-intense impact, water-proofing polyester; Toolbox
Weight 300g
conductivity standard block Verify and guarantee temperature compensation
Measuring range 0.5%IACS-110%IACS(0.29MS/m-64MS/m)
Distinguishing rate 0.01% IACS
Probe compensated 0.3mm
Measuring accuracy

0°C to 45°C

23%IACS :±0.1%IACS

100%IACS:±0.3%IACS

Temperature compensation Automatic compensation to the value of 20 ℃
Normal work environment Relative humidity 0~95%
Operating temperature 0℃~50℃
Data storage Can store 1000 measurement data
Probe

Diameter: 12mm

Applicable to minimum measuring area diameter at 60KHz is 12mm

Diameter: 8mm

Applicable to minimum measuring area diameter at 60KHz is 8mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Accessories

Instrument Host HEC-102, Standard probe 12mm 60KHz , Probe cable, Conductivity standard block aluminum and copper each one, Power adapter, Insulation sleeve, Suitcase, Instrument manual, Calibration certificate

 

Optional Accessories

12mm 60KHz or 120KHz probe

8mm 120KHz or 240KHz probe

Other calibration blocks

Curve probe support for pipe testing

 

Measurement The Purity Of Non-Ferrous Metals Portable Eddy Current Testing Equipment 0

 

Measurement The Purity Of Non-Ferrous Metals Portable Eddy Current Testing Equipment 1

                                                   Curve probe support for pipe testing

 

Products use and maintain

Ⅰ,In order to prevent electric shock or catch fire, please use the suitable power adapter

Ⅱ,Avoid to drop and hit the instrument.

Ⅲ,Please keep the instrument clean and dry, please check the probe and standard block weather are damaged or corrupted before using.

Ⅳ,Please do not operate in wet, explosive, chemic or high temperature environment.

Ⅴ,Do not voluntarily replace the spare part, if the product is abnormal or has suspicious breakdown, please contact with technology department or serviceman of our company for help.

 

Recommended Products
Get in touch with us
Contact Person : JingAn Chen
Tel : 8610 82921131,86 13261934319
Fax : 86-10-82916893
Characters Remaining(20/3000)