| Color | Green |
|---|---|
| Standard | ISO10816,JJG 1062-2010. JJG 298-2015 |
| Frequency | Fixed 10, 20, 40, 80, 160, 320, 640, 1280Hz And External Input For Any Signal With Continuous Frequency Adjustment, Sweep, Non-sine |
| Amplitude Accuracy | Acceleration(@30m/s2 Pk) 40Hz To 320Hz + 0.3dB + 1digit 20Hz To 1280Hz + 0.5dB +1digit Velocity ( @25mm/sec Pk) 40Hz To 320Hz +0.5dB +1digit Displacement(@50μm Pk-pk) 40Hz To 320Hz + 0.5dB + 1digit |
| Proximity Probe Linearity | Prode: 5mm And 8mm Probes Range: 0~2.0mm |
| Color | Green |
|---|---|
| Standard | ISO10816,JJG 1062-2010. JJG 298-2015 |
| Frequency | Fixed 10, 20, 40, 80, 160, 320, 640, 1280Hz And External Input For Any Signal With Continuous Frequency Adjustment, Sweep, Non-sine |
| Amplitude Accuracy | Acceleration(@30m/s2 Pk) 40Hz To 320Hz + 0.3dB + 1digit 20Hz To 1280Hz + 0.5dB +1digit Velocity ( @25mm/sec Pk) 40Hz To 320Hz +0.5dB +1digit Displacement(@50μm Pk-pk) 40Hz To 320Hz + 0.5dB + 1digit |
| Proximity Probe Linearity | Prode: 5mm And 8mm Probes Range: 0~2.0mm |
| Transducer | Piezoelectric Acceleration Transducer |
|---|---|
| Parameters | RMS Of Velocity Values, Peak-peak Value Of Displacement, Peak Values Of Acceleration Or Real-time Spectral Charts |
| Speed Testing | Rotational Speed |
| Standards | GB 13823.3 |
| Display | TFT 320×200 Pixels With RGB |
| Frequency Range | 0.01 ~ 100 Hz (extensible) |
|---|---|
| Stroke | 400 Mm (optional 100 Mm ~ 2m) |
| Max Acceleration | 20 M/s2 (extensible) |
| Distortion Degree | < 5% |
| Lateral Motion Ratio | < 10% |
| Operating System | Win Ce |
|---|---|
| Storage Capacity | 8G |
| Liquid Crystal Display (LCD) | 3.5-inch True Color LCD Screen, 640×480 Pixels |
| Touch Screen | Full Screen Touch Operation |
| Communications | USB |
| Testing Parameters | Velocity |
|---|---|
| Testing Range | Velocity: 0.1mm/s-199.9 Mm/s(RMS) |
| Accuracy | ±5% ± 2digits |
| Display | 3 1/2 Digits LCD |
| Power Supply | Two Button Batteries(LR44 Or SR44) |
| Testing Parameters | Acceleration, Velocity And Displacement Testing |
|---|---|
| Acceleration | 0.1m/s2-199.9m/s2(peak) |
| Velocity | 0.1mm/s-199.9 Mm/s(RMS) |
| Displacement | 0.001mm-1.999 Mm (peak-peak) |
| Accuracy | ±5% ± 2digits |
| Detector | Cesium Iodide And Lithium Fluoride |
|---|---|
| Display | LED |
| Energy Response Time | 50kev~3MeV |
| Dose Rate | 0.01μSv/h~5mSv/h |
| Dose Equivalent Range | 0.01 Sv/h ~ 9.99SV /h |
| Vibration Sensor | 3-Axis Piezoelectric Accelerometer |
|---|---|
| Display | 4 Digit LCD Backlit |
| Testing Range | Velocity : 0.01-400.0 Mm/s 0.000-16.00 Inch/s True RMS Acceleration : 0.1-400.0 M/s² 0.3-1312 Ft/s² 0.0-40g Equivalent Peak Displacement : 0.001-4.000mm 0.04-160.0 Mil Equivalent Peak-peak |
| Frequency Range For Measuring | 10Hz. To 10kHz |
| Accuracy | 5% Of Reading + 2 Digits |
| Measurement Parameter | RMS Of Vibration Velocity (mm/s) |
|---|---|
| Range | 1mm/s~50mm/s At20~1000Hz, 5% |
| Operation Temperature Range | 0 - 50C |
| Size | 160mm X 25mm X 17mm (WxDxH) |
| Weight | 120 Gram (including Battery) |