| Indenter To Wall Distance | 200mm |
|---|---|
| Test Maximum Heigh | Rockwell:220mm、 Brinell Vickers:150mm |
| Tester Size | 560*260*800mm |
| Hardness Scale | HBW1/5、HBW2.5/62.5、HBW1/10、HBW2.5/15.625、HBW1/30、HBW2.5/31.25、HBW2.5/62.5、HBW10/100、HBW5/125、HBW2.5/187.5 (select 10 Scales) |
| Test Force Application Method | Automatic |
| Indenter To Wall Distance | 200mm |
|---|---|
| Test Maximum Heigh | Rockwell:220mm、 Brinell Vickers:150mm |
| Shape Size | 560*260*800mm |
| Hardness Scale | HBW1/5、HBW2.5/62.5、HBW1/10、HBW2.5/15.625、HBW1/30、HBW2.5/31.25、HBW2.5/62.5、HBW10/100、HBW5/125、HBW2.5/187.5 (select 10 Scales) |
| Test Force Application Method | Automatic |
| Test Force | 3000 Kgf (1000 Kgf, 750 Kgf, 500 Kgf Optional) |
|---|---|
| Test Ball | 10mm Carbide Alloy Ball (5mm Optional) |
| Test Range | 32~650 HBW |
| Opening Dimension | 350 Mm (Height) X 100 Mm (Throat Depth) |
| Indicator Error | Complies With ISO 6506, ASTM E10, And ASTM E110 |
| Testing Range | 8~650HBW |
|---|---|
| Max, Height Of The Speciment | 225mm |
| Magnification Of The Microscope | 20X |
| Power Supply And Voltage | AC220V/50-60Hz |
| Principle | Electronic Brinell |
| Digital Screen | Touch Screen |
|---|---|
| Advanced Technology | Auto Turret, Closed-loop Pressure Control, Automatic Loading, Automatic Load; |
| Wide Force Measurement Range | From 62.5 To 3000 Kg |
| Ball Diameter Error Of Less Than | +/- 1 Micron |
| USB Interface | U Disc, Excel File |
| Color | Black |
|---|---|
| Measuring Range | 15.9-650HBW(ASTM E10) |
| Brinell Test Force | 5 Kgf 、6.25 Kgf 、10 Kgf 、15.625 Kgf 、25 Kgf 、30 Kgf 、31.25Kgf 62.5Kgf、187.5Kgf |
| Brinell Hardness Scales | HBW2.5/6.25、HBW2.5/15.625、HBW2.5/31.25、 HBW2.5/62.5、HBW2.5/187.5、HBW1/5、HBW1/10、HBW1/30 |
| Hardness Resolution Ratio | 0.1HBW |
| Digital Screen | Touch Screen |
|---|---|
| Advanced Technology | Auto Turret, Closed-loop Pressure Control, Automatic Loading, Automatic Load; |
| Wide Force Measurement Range | From 62.5 To 3000 Kg |
| Indentation Measurement Resolution | 1 Micron |
| Ball Diameter Error Of Less Than | +/- 1 Micron |
| Brinell Scale | HBW2.5/31.25 HBW2.5/62.5 HBW2.5/187.5 HBW5/62.5 |
|---|---|
| Rockwell Scale | HRA HRB HRC HRD HRE HRF HRG HRK HRH |
| Vickers Scale | HV30 HV100 |
| Packaging Details | Standard export package |
| Delivery Time | 1-4days |
| System | Innovative Closed-loop Technology |
|---|---|
| Standards | ASTM E-10 ISO6506 |
| Display | LCD |
| Max Measurable Height | 230 Mm |
| Max Measurable Depth | 140 Mm |
| Standard | ISO6506 ASTM E-10 |
|---|---|
| Statistics Values | Max, Min, Avg, R And S Are Available |
| Convertable | HRC, HRB, HRA, HV, σb |
| Test Report | Created In Microsoft EXCEL Format, Can Be Edit, Copy, Print As You Will |
| Load Dwell Duration | 2s~99s, Can Be Set And Stored |